← Back to the certified product directory

Source-backed model record

Rheem PROPH50 T0 RH120-MSO

This page separates current ENERGY STAR certification fields from independently reviewed manufacturer fields. It is not a purchase recommendation or an installation approval.

Product details

Decision briefing from current source records

Use these source-backed facts to identify what can be compared and where current data is unavailable. They do not establish household fit, installation approval, operating cost, price, availability, or a preferred model.

Hot-water delivery and tank

Compare these listed values with a hot-water requirement you determined independently. No listed value establishes household fit by itself.

Hot-water delivery and tank decision facts
Source layer and fieldCurrent source-backed status
ENERGY STARENERGY STAR storage volume 46 gal
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ENERGY STARENERGY STAR first-hour rating 55 gal
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ManufacturerManufacturer nominal tank capacity 50 gal
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerManufacturer storage volume 46 gal
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerManufacturer first-hour rating 55 gal
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerManufacturer recovery rate 12 gal/hour
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.

Physical fit and service access

Compare product dimensions with measured space. Product dimensions are not installation clearances; verify every clearance and service-access requirement separately.

Physical fit and service access decision facts
Source layer and fieldCurrent source-backed status
ManufacturerProduct height 62 in
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerProduct diameter 22.25 in
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerEmpty weight 178 lb
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.

Electrical requirements

Compare only with circuit information confirmed for the installation. Verify the current instructions and required work with a qualified professional.

Electrical requirements decision facts
Source layer and fieldCurrent source-backed status
ENERGY STARENERGY STAR input voltage 120 V
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ManufacturerManufacturer input voltage 120 V
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerRecommended breaker size 15 A
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerCircuit requirement 120V shared circuit
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4 section heading: ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerConnection type Plug-in
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4 section heading: ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit Verified 2026-08-20; revalidation due before 2026-09-19.

Location, air, ducting, and condensate

Confirm each published location, airflow, temperature, ducting, and drain requirement. An unavailable value is an unresolved check, not permission.

Efficiency and operating information

These are listed product metrics, not a prediction of household energy use, utility cost, or savings.

Efficiency and operating information decision facts
Source layer and fieldCurrent source-backed status
ENERGY STARENERGY STAR heat-pump type 120 Volt Integrated HPWH
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ENERGY STARENERGY STAR fuel Electric
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ENERGY STARENERGY STAR Uniform Energy Factor 3
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ENERGY STARENERGY STAR listed annual electric usage 1072 kWh/year
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ManufacturerManufacturer Uniform Energy Factor 3
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.
ManufacturerHeat-pump capacity 4200 Btu/hour
Verified valueSource: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row Verified 2026-08-20; revalidation due before 2026-09-19.

Sound and documented features

These rows report only currently verified exact-model facts. A missing feature value does not mean the feature is absent.

Sound and documented features decision facts
Source layer and fieldCurrent source-backed status
ManufacturerConnectivity supported Yes — verifiedSource: Rheem ProTerra Plug-in specifications, Page 4 note below all three exact-model tables Verified 2026-08-20; revalidation due before 2026-09-19.

Certification and source record

Use the source links and dates to validate the exact model and current evidence before choosing.

Certification and source record decision facts
Source layer and fieldCurrent source-backed status
ENERGY STARENERGY STAR source record ID 3555171
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
ENERGY STARENERGY STAR certification date 2024-11-04
Verified valueSource: ENERGY STAR certified-product dataset Verified 2026-09-01; revalidation due before 2026-09-04.
Full technical facts and field-level evidence

ENERGY STAR certification fields

ENERGY STAR ID
3555171
Heat-pump type
120 Volt Integrated HPWH
Fuel
Electric
Uniform Energy Factor
3
Storage volume
46 gal
First-hour rating
55 gal
Listed annual electric usage
1072 kWh/year
Input voltage
120 V
Date certified
2024-11-04

Open the authoritative ENERGY STAR record (opens in a new tab)

Verified manufacturer fields

Each value below is tied to the exact model, retained source bytes, a field locator, and a current review interval. Dimensions do not include required clearances unless a clearance field is shown separately.

Identity

Manufacturer Name
Rheem Source: Rheem ProTerra Plug-in specifications, Page 4 heading: Rheem ProTerra Plug-in Specifications

Physical

Nominal Tank Capacity Gallons
50 gal Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Storage Volume Gallons
46 gal Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Height Inches
62 in Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Diameter Inches
22.25 in Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Empty Weight Pounds
178 lb Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Shipping Weight Pounds
218 lb Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row

Electrical

Input voltage
120 V Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Recommended Breaker Amps
15 A Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Circuit Requirement
120V shared circuit Source: Rheem ProTerra Plug-in specifications, Page 4 section heading: ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit
Connection Type
Plug-in Source: Rheem ProTerra Plug-in specifications, Page 4 section heading: ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit

Performance

Uniform Energy Factor
3 Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
First Hour Rating Gallons
55 gal Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Recovery Rate Gallons Per Hour
12 gal/hour Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row
Heat Pump Capacity Btu Per Hour
4200 Btu/hour Source: Rheem ProTerra Plug-in specifications, Page 4, ProTerra Plug-in Heat Pump Water Heater with HydroBoost and LeakGuard – 120V Shared Circuit, exact PROPH50 T0 RH120-MSO row

Features

Connectivity Supported
Yes Source: Rheem ProTerra Plug-in specifications, Page 4 note below all three exact-model tables

Fields that cannot support a decision yet

Show 43 fields not yet verified

These fields have no verified exact-model claim in the current research record. They may not yet have been reviewed or may not appear in an eligible source. Unknown does not mean zero, false, not required, or compatible.

  • Identity Model Family Name: unknown pending exact-model verification.
  • Identity Model Aliases: unknown pending exact-model verification.
  • Physical Width Inches: unknown pending exact-model verification.
  • Physical Depth Inches: unknown pending exact-model verification.
  • Electrical Phases: unknown pending exact-model verification.
  • Electrical Frequency Hz: unknown pending exact-model verification.
  • Electrical Minimum Circuit Ampacity Amps: unknown pending exact-model verification.
  • Electrical Maximum Overcurrent Protection Amps: unknown pending exact-model verification.
  • Installation Allowed Location Types: unknown pending exact-model verification.
  • Installation Minimum Room Volume Cubic Feet: unknown pending exact-model verification.
  • Installation Side Clearance Inches: unknown pending exact-model verification.
  • Installation Front Service Clearance Inches: unknown pending exact-model verification.
  • Installation Top Clearance Inches: unknown pending exact-model verification.
  • Installation Rear Clearance Inches: unknown pending exact-model verification.
  • Installation Floor Support Requirement: unknown pending exact-model verification.
  • Installation Seismic Anchoring Requirement: unknown pending exact-model verification.
  • Installation Orientation Requirement: unknown pending exact-model verification.
  • Performance Annual Electric Usage Kwh: unknown pending exact-model verification.
  • Performance Resistance Element Watts: unknown pending exact-model verification.
  • Performance Maximum Setpoint Fahrenheit: unknown pending exact-model verification.
  • Performance Certifications: unknown pending exact-model verification.
  • Modes Operating Modes: unknown pending exact-model verification.
  • Modes Mode Descriptions: unknown pending exact-model verification.
  • Sound Rated Sound Level Dba: unknown pending exact-model verification.
  • Sound Sound Test Context: unknown pending exact-model verification.
  • Ambient Minimum Operating Air Temperature Fahrenheit: unknown pending exact-model verification.
  • Ambient Maximum Operating Air Temperature Fahrenheit: unknown pending exact-model verification.
  • Ambient Operating Temperature Context: unknown pending exact-model verification.
  • Ducting Ducting Supported: unknown pending exact-model verification.
  • Ducting Inlet Duct Diameter Inches: unknown pending exact-model verification.
  • Ducting Outlet Duct Diameter Inches: unknown pending exact-model verification.
  • Ducting Maximum Equivalent Duct Length Feet: unknown pending exact-model verification.
  • Ducting Duct Configuration Notes: unknown pending exact-model verification.
  • Condensate Condensate Drain Required: unknown pending exact-model verification.
  • Condensate Drain Connection Size Inches: unknown pending exact-model verification.
  • Condensate Condensate Pump Included: unknown pending exact-model verification.
  • Condensate Drain Notes: unknown pending exact-model verification.
  • Features Documented Features: unknown pending exact-model verification.
  • Features Leak Detection Supported: unknown pending exact-model verification.
  • Features Demand Response Capable: unknown pending exact-model verification.
  • Features Integrated Mixing Valve: unknown pending exact-model verification.
  • Features Backup Resistance Elements: unknown pending exact-model verification.
  • Features Recirculation Supported: unknown pending exact-model verification.

Reviewed sources

Validate before choosing

Confirm the exact model, current instructions, electrical requirements, clearances, airflow, condensate path, and local-code requirements with the manufacturer and a qualified installer.

No exact-model manufacturer product page is currently eligible as a commercial next step.